Identify the Missing PCS 7 Package Behind “Open (257:8)”

Identify the Missing PCS 7 Package Behind “Open (257:8)”

The PCS 7 message open (257:8) saying that an object of type 12E1A47 cannot be represented indicates that the installed engineering environment is missing a software package needed to display or edit an object in the project. Do not guess the package from 12E1A47: use the missing-package list shown when the project opens and confirm it in SIMATIC Manager under the project's Required software packages tab. Install the package and version required by the project before editing.

Table of Contents

Interpret the error without guessing the package

The ticket reports open (257:8), the object type 12E1A47, and the message that one or more objects cannot be represented and required software packages should be installed. The reply explains that a project can contain objects created by an optional STEP 7/PCS 7 package that is not installed on the current engineering station.

The identifier 12E1A47 is the reported object type, not the name of the missing package. The source does not identify the exact package or the STEP 7/PCS 7 version. Siemens documentation describes a project-level method to determine required software packages and versions.

Use the package list shown when opening the project

  1. Open the project in SIMATIC Manager and acknowledge the object-representation warning.
  2. Review the dialog or list that names the software packages missing on the engineering computer. Record each package and version shown.
  3. Compare the listed requirements with the software and options installed on the engineering station.
  4. Obtain and install the required software package at the project-compatible version, following its own Siemens installation instructions.
  5. Reopen the project and verify that the warning no longer appears and that the affected hardware-configuration objects are displayed.

The list supplies the actionable package information. The error's numeric object-type identifier alone does not.

Check the Required software packages project property

Siemens' STEP 7 programming manual documents this check in SIMATIC Manager: select the project, open Edit > Object Properties, and select the Required software packages tab. Review the packages and versions required for editing.

The manual notes that the requirement information is complete when the project or library was created in STEP 7 V5.2 or later and the project has been checked for software packages used in its creation. If the tab indicates that a check is needed, or if the package list does not explain the error, perform the project check using the procedure supported by the installed STEP 7 version and review the resulting requirements. A project property check can identify dependencies; it does not install them.

Verify after installing the package

Reopen the same project with the required package installed. Confirm that the hardware configuration opens and the previously unrepresented object is visible. If the warning persists, compare the actual installed package/version with the requirement list and check for other missing packages; the project may depend on more than one option package.

Do not delete, replace or recreate the unrepresented object merely to bypass the warning. First establish the package dependency and preserve the project before making changes.

Verification

Record the STEP 7/PCS 7 version, the complete warning text, the exact package and version shown by the project, and the installed package version. Reopen the hardware configuration and confirm that the reported object is represented. If the project property tab says its package information may be incomplete, do not treat the current list as exhaustive until the documented check has been completed.

Limitations and Operational Precautions

The source does not provide the package name, source engineering version, or full details of the project. No Siemens reference found maps object type 12E1A47 specifically to a package. The exact required software therefore must be read from the project's missing-package report or property tab.

Installing optional engineering software can change the engineering workstation environment. Use the supported package version, back up the project, and follow the system's software management controls. Opening a project and viewing its hardware configuration are distinct from changing or downloading it; do not download project changes as part of this package-identification task.

Engineer FAQ

What package should be installed for open (257:8)?

The error text alone does not identify it. Read the missing-package list shown during project opening or inspect the project's Required software packages tab.

Does 12E1A47 name the required package?

No. It is reported as an object type that cannot be represented. The source and checked Siemens references do not map it to a package name.

Where is the Required software packages tab?

In SIMATIC Manager, select the project and use Edit > Object Properties, then open the Required software packages tab, as documented in the STEP 7 programming manual.

What if the project property does not show all dependencies?

The manual says completeness depends on project creation in STEP 7 V5.2 or later and checking the project for used software packages. Follow the check procedure for the installed STEP 7 version and review any package list shown during opening.

Technical References

  1. Siemens, Programming with STEP 7, Manual, 04/2017, A5E41552389-AA, section 6.7.1 “Checking Projects for Software Packages Used,” pp. 150–151: https://cache.industry.siemens.com/dl/files/825/109751825/att_933142/v1/STEP_7_-_Programming_with_STEP_7.pdf
  2. Siemens, STEP 7 Error Codes, Version 01/2014, reference table for “One or more objects of a type cannot be represented.” The available table lists examples involving missing optional packages, but does not identify object type 12E1A47: https://support.industry.siemens.com/cs/attachments/770453/770453_STEP7_ErrorCode_e.pdf

Related Articles

Find software packages required by a SIMATIC Manager project

Troubleshoot STEP 7 objects that cannot be represented